Eac, erc profiles - pressure valve(s), 9ć53, Span your valves chapter 9 – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 219: Confirm critical values

Advertising
background image

Span Your Valves

Chapter 9

9-53

Span your ejector pressure valve(s) for optimum pressure performance.
Do this in four parts:

Confirm critical values
Span your ejector pressure valve(s)
Test valve linearity with an ejector pressure profile
Set pressure alarm setpoints

Important: Omit the procedure Span your ejector pressure valve(s) in this
section if the recorded manufacturer’s valve spanning data for pressure
control limits EAC41-44 and ERC41-44 are adequate for your application.

Confirm Critical Values

Important: Confirm that all entries you made for configuration values
(chapter 7) and profile values (chapter 8) are as follows:

On Worksheet: Confirm Your Configuration:

With These Words or Bits:

ProĆset Addr:

7ĆM, 7ĆN

QDC module output to which you connected

your selected pressure control valve

EAC02ĆB06, B05, B04 = your selection

ERC02ĆB06, B05, B04 = your selection

B39/22, 21, 20

B37/86, 85, 84

Unselected setĆoutput values for outputs 1Ć4

EAC09Ć12 = ERC09Ć12 = your value

N45:05Ć08, N45:65Ć68

All ramping is disabled with zero ramp rates

EAC17Ć20,25Ć28 = ERC17Ć20,25Ć28 = 0

N45:13Ć16,21Ć24, N45:73Ć76,81Ć84

Pressure limits:

Minimum Control Limit

Maximum Control Limit

Selected Pressure Valve, Output for Min

Selected Pressure Valve, Output for Max

EAC41 = ERC41 = 0

EAC42 = ERC42 = system pressure

EAC43 = ERC43 = your value

EAC44 = ERC44 = your value

N45:37, 97

N45:38, 98

N45:39, 99

N45:40, 100

8ĆF

Forward dwell - apply after final stroke

EPC03ĆB15 = 0

B39/175

Type of stroke - all full strokes

EPC03ĆB13 = 0

B39/173

Continue or stop/notify - your selection

EPC03ĆB12

B39/172

Ejector profile On/Off - profile On

EPC03ĆB09 = 0

B39/169

Logical bridge - start on command from PLC

EPC03ĆB08 = 1

B39/168

Profile algorithm - pressure vs. position

EPC03ĆB00 = 1

B39/160

Expert Response Compensation (ERC) = Off

EPC04ĆB09 = B08 = 1

B39/185Ć184

OpenĆloop control

EPC04ĆB01 = B00 = 1

B39/177Ć176

EPC velocity setpoints

EPC09, 12, 15, 21, 27, 33, 36, 39 = zero N45:125,128,131,137,143,149,152,155

EPC pressure setpoints

EPC10, 34 = your value

EPC13, 16, 22, 28, 37, 40 = zero

N45:126, 150

N45:129,132,138,144,153,156

EPC endĆofĆsegment position setpoints

EPC11, 14, 23, 29, 35, 38 = zero

N45:127,130,139,145,151,154

Ejector forward dwell timer preset

EPC57 = zero

N45:173

Ejector full advance position setpoint

EPC59 = your value

N45:175

Ejector full retract position setpoint

EPC60 = your value

N45:176

Clamp position for start ejector profile

EPC61 = value in OPC62

N45:177

Clamp position for ejector inhibit

EPC62 = your value

N45:178

Ejector position for clamp close enable

EPC63 = your value

N45:179

Ejector strokes required

EPC64 = one

N45:180

If these are not your current values, we suggest that you correct them now
using the download procedure discussed in chapter 4.

EAC, ERC Profiles -

Pressure Valve(s)

Advertising