Chapter 2 - install the qdc module, Chapter objectives, Record i/o ranges – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 33: Install the qdc module, Chapter objectives record i/o ranges

Advertising
background image

Chapter

2

2-1

Install the QDC Module

This chapter helps you install the QDC module with these procedures:

record I/O ranges
set module jumpers
key the I/O chassis
install the QDC module
wire I/O devices to the QDC module
ground and shield I/O devices
plan for E-STOPs and machine interlocks

To match your QDC module to your I/O devices, record the I/O ranges of
your I/O devices on Worksheet 2-A. You will use this information in this
chapter for hardware configuration (setting jumper plugs) and in chapter 4
to configure the module’s inputs and outputs with software.

Circle or check the I/O ranges on Worksheet 2-A. Cross off I/O not used.

Worksheet 2ĆA

Record I/O Ranges

I/O Connection:

Voltage 1:

Voltage 2:

Current:

Input 1 (Screw position)

0 to 10V dc

1 to 5V dc

4 to 20 mA

Input 2 (System pressure)

0 to 10V dc

1 to 5V dc

4 to 20 mA

Input 3 (Clamp position)

0 to 10V dc

1 to 5V dc

4 to 20 mA

Input 4 (Ejector position)

0 to 10V dc

1 to 5V dc

4 to 20 mA

Output 1

Ć10 to 10V dc

0 to 10V dc

4 to 20 mA

Output 2

Ć10 to 10V dc

0 to 10V dc

4 to 20 mA

Output 3

Ć10 to 10V dc

0 to 10V dc

4 to 20 mA

Output 4

Ć10 to 10V dc

0 to 10V dc

4 to 20 mA

Chapter Objectives

Record I/O Ranges

Advertising