Jog Your Machine

Chapter 5

5-4

ATTENTION: You can connect up to four different valves to
your QDC module. Although all four may not directly jog the
ram (screw), clamp, and/or ejector, consider their indirect effect
when setting jog set-output values. Indirectly, they could cause
unexpected machine motion with possible damage to equipment
or injury to personnel.

ATTENTION: A value of 0 entered in your data table does not
necessarily correspond to zero pressure or flow. For an output
configured + 10V dc, an output of 50% corresponds to zero
volts signal output (see graph). Amplifier electronics or spool
offsets may also be designed such that zero volts signal input
does not result in no flow or pressure. Please consult your valve
and amplifier specifications for more details.

-10

-5

0

5

10

0

10 20 30 40 50 60 70 80 90 100

% Output Requested

Output V

oltage

Enter and Download Initial Jog Values

Enter values from Worksheet 5-A into PLC-5 data table and download the
JGC block to the QDC module with your programming terminal. Use the
procedures from chapter 4, Enter Data Table Values and Download Data
Blocks
. We repeat the JGC block download data.