Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 98

Advertising
background image

Enter Your Values Here

Load Initial Configuration Values

Chapter 7

7-12

Worksheet 7ĆE (continued)
Hold Configuration Block (HDC)

Control Word ProĆSet 600 Addr. Value

Description

Units

HDC06

N44:182

1000

Minimum ERC PercentageĆĆPressure

Percent

8

HDC09

N44:185

*

Output #1 SetĆoutput Value During Profile

Percent Signal Output

4

HDC10

N44:186

*

Output #2 SetĆoutput Value During Profile

Percent Signal Output

4

HDC11

N44:187

*

Output #3 SetĆoutput Value During Profile

Percent Signal Output

4

HDC12

N44:188

*

Output #4 SetĆoutput Value During Profile

Percent Signal Output

4

HDC17

N44:193

0

Output #1 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

HDC18

N44:194

0

Output #2 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

HDC19

N44:195

0

Output #3 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

HDC20

N44:196

0

Output #4 Acceleration Ramp Rate During Profile

Percent Signal Output per Second

5

HDC25

N44:201

0

Output #1 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

HDC26

N44:202

0

Output #2 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

HDC27

N44:203

0

Output #3 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

HDC28

N44:204

0

Output #4 Deceleration Ramp Rate During Profile

Percent Signal Output per Second

5

HDC33

N44:209

*

Output #1 SetĆoutput Value at EndĆof Profile

Percent Signal Output

4

HDC34

N44:210

*

Output #2 SetĆoutput Value at EndĆof Profile

Percent Signal Output

4

HDC35

N44:211

*

Output #3 SetĆoutput Value at EndĆof Profile

Percent Signal Output

4

HDC36

N44:212

*

Output #4 SetĆoutput Value at EndĆof Profile

Percent Signal Output

4

HDC41

N44:217

0

Pressure Minimum Control Limit

Pressure

3

HDC42

N44:218

*

Pressure Maximum Control Limit

Pressure

3

HDC43

N44:219

*

Selected Pressure Valve, Output for Minimum

Percent Signal Output

4

HDC44

N44:220

*

Selected Pressure Valve, Output for Maximum

Percent Signal Output

4

HDC49

N44:225

100

Proportional Gain for Pressure Control

None

HDC50

N44:226

400

Integral Gain for Pressure Control

Inverse Time (algorithm)

6

HDC51

N44:227

0

Derivative Gain for Pressure Control

Time (algorithm)

7

HDC57

N44:233

0

Profile High Pressure Alarm Setpoint

Pressure

3

3

Pressure

4

Percent Signal Output

0000 to 9999 PSI 00.00 to 99.99

000.0 to 999.9 Bar

5

Percent Signal Output per Second

6

Inverse Time (Algorithm)

7

Time (Algorithm)

8

Percent

0000 to 9999 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99

00.00 to 99.99 Seconds (AĆB) 00.00 to 99.99 Seconds (AĆB)

* Refer to the appropriate section later in this chapter for information on this parameter

Advertising