Configure the QDC Module's I/O

Chapter 3

3-4

To determine initial sensor configuration values, refer to Table 3.A, and
specifications that accompanied your sensors, valves, and cylinders. Write
down applicable values on Worksheet 3-D.

Important: You must enter floating-point numbers and percentages as
integers, so we recommend that you write them in Worksheet 3-D in the
following format: Use an assumed decimal point position that depends on
the range value. For example:

If the Range is:

And You Want to

Enter this Value:

Use this

Format:

0 Ć 099.99%

75%

07500

0 Ć 99.99 inch

7.32 inch

00732

0 Ć 0999.9 mm

432.6 mm

4326

4.00 Ć 020.00 mA

16 mA

01600

0 Ć 010.00V dc

5.6V dc

00560

0 Ć 009.99 sec

0.47 sec

00047

0 Ć 09999 psi

321 psi

00321

0 Ć 0999.9 Bar

222 Bar

2220

Table 3.A

Determine Initial SensorĆconfiguration Values for Worksheet 3ĆD

Category:

If your:

Then Use a Value Equal to:

Minimum Position (Lines 1, 9, and 13)

N/A

zero

Maximum Position (Lines 2, 10, and 14)

Actuator is fully extended

full travel of the sensor

Analog Signal @ Min Position

sensor is forwardĆacting

low end of your selected range

(Lines 3, 11, and 15) sensor is reverseĆacting

high end of your selected range

Analog Signal @ Max Position

sensor is forwardĆacting

high end of your selected range

(Lines 4, 12, and 16) sensor is reverseĆacting

low end of your selected range

Minimum System Pressure (Line 5)

N/A

min range value specified by manufacturer

Maximum System Pressure (Lines 6)

N/A

max range value specified by manufacturer

Analog Signal @ Min System Pressure

sensors are forwardĆacting

low end of your selected range

(Line 7) sensors are reverseĆacting

high end of your selected range

Analog Signal @ Max System Pressure

sensors are forwardĆacting

high end of your selected range

(Line 8)

sensors are reverseĆacting

low end of your selected range

Determine Initial

SensorĆconfiguration Values