Enter Your PressureĆalarm and TimeĆdelay Values Here
Blank Worksheets
Appendix A
A-5
Worksheet 4ĆG
PressureĆalarm and TimeĆdelay Setpoints
Control Word
ProĆSet 600 Addr. Value
Description
Units
MCC21
N40:17
Screw PressureĆalarm Setpoint
Ram (screw) Pressure
2
MCC22
N40:18
ScrewĆpressure TimeĆdelay Setpoint
Time Measured in Seconds
1
MCC35
N40:31
Clamp PressureĆalarm Setpoint
Clamp Pressure
2
MCC36
N40:32
ClampĆpressure TimeĆdelay Setpoint
Time Measured in Seconds
1
1
Time Measured in Seconds
2
Pressure
00.00 to 00.99
0000 to 9999 PSI
000.0 to 999.9 Bar