Span Your Valves

Chapter 9

9-42

Span your clamp open pressure valve(s) for optimum performance. Do
this in four parts:

Confirm critical values
Span your clamp open pressure valve(s)
Test valve linearity
Set profile pressure alarms

Important: You may omit the procedure Span your clamp open pressure
valve(s)
in this section if the recorded valve spanning data from the manu-
facturer for pressure control limits FOC41-44, SOC41-44, TOC41-44, and
OSC41-44 (chapter 7) are adequate for your application.

Confirm Critical Values

Important: Confirm that your entries for configuration values (chapter 7)
and profile values (chapter 8) for clamp open profiles are as follows:

On Worksheet: Confirm Your Configuration:

With These Words or Bits:

ProĆset Addr:

7ĆI, 7ĆJ, 7ĆK, 7ĆL QDC module output to which you connected

your selected pressure control valve

FOC02ĆB06, B05, B04 = your selection

SOC02ĆB06, B05, B04 = your selection

TOC02ĆB06, B05, B04 = your selection

OSC02ĆB06, B05, B04 = your selection

B37/342, 341, 340

B37/406, 405, 404

B37/470, 469, 468

B37/534, 533, 532

Your unselected setĆoutput values for outputs

1Ć4

FOC09Ć12 = your selection

SOC09Ć12 = your selection

TOC09Ć12 = your selection

OSC09Ć12 = your selection

N43:305Ć308

N43:365Ć368

N43:425Ć428

N43:485Ć488

All ramping is disabled with zero ramp rates

FOC17Ć20 = FOC25Ć28 = 0

SOC17Ć20 = SOC25Ć28 = 0

TOC17Ć20 = TOC25Ć28 = 0

OSC17Ć20 = OSC25Ć28 = 0

N43:313Ć316

N43:321Ć324

N43:373Ć376

N43:381Ć384

N43:433Ć436

N43:441Ć444

N43:493Ć496

N43:501Ć504

Pressure limits:

Minimum Control Limit

Maximum Control Limit

Selected Pressure Valve, Output for Min

Selected Pressure Valve, Output for Max

FOC41=SOC41=TOC41=OSC41=0

FOC42=SOC42=TOC42=OSC42=sys press

FOC43=SOC43=TOC43=OSC43=your value

FOC44=SOC44=TOC44=OSC44=your value

N43:337, 397, 457, 517

N43:338, 398, 458, 518

N43:339, 399, 459, 519

N43:340, 400, 460, 520

8ĆE

Mold Protection - start open slow on overrun

OPC03ĆB11 = 0

B37/619

Logical bridge - start next profile

OPC03ĆB10 = B09 = B08 = 0

B37/618, 617, 616

Pressure vs. Position control

OPC03ĆB06 = 04 = 02 = 00 = 1

B37/614, 612, 610, 608

Expert Response Compensation (ERC) = Off

OPC04ĆB15 - B08 = 1

B37/639Ć632

OpenĆloop control

OPC04ĆB07 - B00 = 1

B37/631Ć624

FOC segment pressures

OPC10, 13, 16 = your values

N43:546, 549, 552

FOC endĆofĆsegment position setpoints

OPC11, 14, 17 = your values

N43:547, 550, 553

Start OSC position setpoint

OPC61 = your value

N43:597

Mold full open position setpoint

OPC62 = your value

N43:598

FOC, SOC, TOC, OSC