Jog Your Machine

Chapter 5

5-2

Worksheet 5-A lists all words in which you must enter values to
successfully configure your QDC module for jogging the ram (screw),
clamp, and ejector in both directions. Use it to record:

initial

values

Enter initial values just sufficient to jog in the desired direction.
Keep this information in mind:

The numbers you enter are %-signal output.
For a range of –10 to +10V dc, zero output occurs @ 50%

(See Warning on next page.)

Later in this chapter you modify these values to obtain desired results.

pressure alarm setpoints for ram (screw), clamp, and/or ejector jogs

The QDC module sets an alarm any time system pressure equals or
exceeds the corresponding alarm setpoints during a jog. A zero entry
inhibits alarm actuation.

Important: The system high pressure alarm that you set in chapter 4 is
also active during jog functions.

Determine Initial Jog Values