Jog Your Machine
Chapter 5
5-2
Worksheet 5-A lists all words in which you must enter values to
successfully configure your QDC module for jogging the ram (screw),
clamp, and ejector in both directions. Use it to record:
initial
values
Enter initial values just sufficient to jog in the desired direction.
Keep this information in mind:
The numbers you enter are %-signal output.
For a range of –10 to +10V dc, zero output occurs @ 50%
(See Warning on next page.)
Later in this chapter you modify these values to obtain desired results.
pressure alarm setpoints for ram (screw), clamp, and/or ejector jogs
The QDC module sets an alarm any time system pressure equals or
exceeds the corresponding alarm setpoints during a jog. A zero entry
inhibits alarm actuation.
Important: The system high pressure alarm that you set in chapter 4 is
also active during jog functions.
Determine Initial Jog Values