Span Your Valves

Chapter 9

9-15

Span your clamp close velocity (flow) valve(s) for optimum velocity
performance. Do this in three parts:

Confirm critical values
Span your clamp close velocity (flow) valve(s)
Test valve linearity with a velocity vs. position profile

Important: You may omit the procedure Span your clamp close velocity
(flow) valve(s)
if the recorded valve spanning data from the manufacturer for
velocity control limits FCC45-48, SCC45-48, and TCC45-45 (chapter 7) are
adequate for your application.

Confirm Critical Values

Important: Confirm that your entries for configuration values (chapter 7)
and profile values (chapter 8) for clamp close profiles are as follows:

On Worksheet: Confirm Your Configuration:

With These Words or Bits:

ProĆSet Addr.

7ĆA, 7ĆB, 7ĆC

QDC module output to which you connected

your selected velocity control valve

FCC02ĆB02,B01,B00 = your selection

SCC02ĆB02,B01,B00 = your

selection

TCC02ĆB02,B01,B00 = your selection

B37/18, 17, 16

B37/82, 81, 80

B37/146,145,144

Your unselected setĆoutput values for outputs

1Ć4

FCC09Ć12 = your value

SCC09Ć12 = your value

TCC09Ć12 = your value

N43:5Ć8

N43:65Ć68

N43:125Ć128

All ramping is disabled with zero ramp rates

FCC17Ć20 = FCC25Ć28 = 0

SCC17Ć20 = SCC25Ć28 = 0

TCC17Ć20 = TCC25Ć28 = 0

N43:13Ć16 N43:21Ć24

N43:73Ć76 N43:81Ć84

N43:133Ć136 N43:141Ć144

Velocity limits:

Minimum Control Limit

Maximum Control Limit

Selected Velocity Valve, Output for Min

Selected Velocity Valve, Output for Max

FCC45=SCC45=TCC45=0

FCC46=SCC46=TCC46=sys vel

FCC47=SCC47=TCC47=your value

FCC48=SCC48=TCC48=your value

N43:41, 101, 161

N43:42, 102, 162

N43:43, 103, 163

N43:44, 104, 164

8ĆA

Selected inches/second as velocity units

CPC03ĆB14 = 1

B37/302

Mold protection

CPC03ĆB11 = 0

B37/299

Logical bridge

CPC03ĆB10 = B09 = B08 = 0

B37/298, 297, 296

Expert Response Compensation (ERC) = Off

CPC04ĆB15 = B13ĆB08 = 1

B37/319, 317Ć312

OpenĆloop control

CPC04ĆB07 = B05ĆB00 = 1

B37/311, 309Ć304

EndĆof Segment position setpoints

CPC11,14,17

N43:247, 250, 253

Start LPC position

CPC61

N43:297

Mold Safe Position

CPC62

N43:298

If these are not your current values, we suggest that you correct them now
using the download procedure discussed in chapter 4.

FCC, SCC, TCC Profiles -