Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 85

Advertising
background image

Select Command and Status Bits to

Sequence Machine Operation

Chapter 6

6-9

Table 6.G

Command and Configuration Bits

Operation:

Function Enabled

(when = 1):

QDC Block

Address:

ProĆSet

B34/xx:

NonĆprofiled

execute setĆoutput

DYC01ĆB08

392

Action Commands execute unassigned # 1 jog

DYC01ĆB09

393

execute ram (screw) forward jog

DYC01ĆB10

394

execute ram (screw) reverse jog

DYC01ĆB11

395

execute clamp forward jog

DYC01ĆB12

396

execute clamp reverse jog

DYC01ĆB13

397

execute ejector advance jog

DYC01ĆB14

398

execute ejector retract jog

DYC01ĆB15

399

Profile Action

execute 1st clamp close profile

DYC02ĆB00

400

Commands

execute 2nd clamp close profile

DYC02ĆB01

401

execute 3rd clamp close profile

DYC02ĆB02

402

execute LP clamp close profile

DYC02ĆB03

403

execute injection profile

DYC02ĆB04

404

execute pack profile

DYC02ĆB05

405

execute hold profile

DYC02ĆB06

406

execute preĆdecompression movement

DYC02ĆB07

407

execute plastication profile

DYC02ĆB08

408

execute postĆdecompression movement

DYC02ĆB09

409

execute 1st clamp open profile

DYC02ĆB10

410

execute 2nd clamp open profile

DYC02ĆB11

411

execute 3rd clamp open profile

DYC02ĆB12

412

execute clamp open slow profile

DYC02ĆB13

413

execute ejector profile

DYC02ĆB14

414

Stop Command

execute all stop (outputs = zero)

DYC02ĆB15

415

Miscellaneous

reset tonnage watchdog timer

DYC03ĆB00

416

Commands

reset cure timer

DYC03ĆB01

417

reset SYS01ĆB08

DYC03ĆB08

424

reset latched alarms

DYC03ĆB09

425

reset complete bits

DYC03ĆB10

426

continue ejector profile

DYC03ĆB15

431