Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual
Page 136

HPC Block Identifier
Hold/PreĆdecompression
Logical Bridging
0=Start Movement
1=Stop and set outputs
PreĆdecompression/Plastication
Logical Bridging
0=Start Plastication
1=Stop and set outputs
Profile Offset Sign
1=Negative 0=Positive
13=Pack
15=Hold
Open/Closed Loop
1=Open 0=Closed
Enable/Disable ERC
1=Off 0=On
00=Pack
02=Hold
08=Pack
10=Hold
Code:
Your value
0 or 1
Required initial value
loaded by ProĆSet 600
Value not used
0
Load Initial Profile Setpoints
Chapter 8
8-19
Worksheet 8ĆC
Pack/Hold Profile Block (HPC)
Control Word HPC01ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B38/bit
271 270 269 268 267 266 265 264 263 262 261 260 259 258 257 256
Value
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
Control Word HPC03ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B38/bit
303 302 301 300 299 298 297 296 295 294 293 292 291 290 289 288
Value
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
Control Word HPC04ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B38/bit
319 318 317 316 315 314 313 312 311 310 309 308 307 306 305 304
Value
0
0
0
0
0
1
0
1
0
0
0
0
0
1
0
1