Span Your Valves

Chapter 9

9-52

Important: If downloading from your programming terminal, download
FOC followed by OPC with download bits B21/16 and 20 (chapter 4).

6.

Copy final FOC48 (N43:344) into SOC48, TOC48 and OSC48
(N43:404, 464, and 524), and download these changes.

Important: If downloading from your programming terminal, download
FOC, SOC, TOC and/or OSC followed by OPC (chapter 4).

To download:

Set B21/

FOC

16

SOC

17

TOC

18

OSC

19

OPC

20

What You Have Accomplished

The valve spanning procedure you just completed has defined the:

range of velocity available during any clamp open profile

end-of-range maximum and minimum signal levels for linear control of

the clamp velocity valve in open-loop control:

For this

range limit

When trying to obtain the

velocity in:

The QDC module drives the selected

velocity valve to % output signal in:

Minimum

FOC45,SOC45,TOC45,OSC45 FOC47, SOC47, TOC47, and OSC47

Maximum

FOC46,SOC46,TOC46,OSC46 FOC48, SOC48, TOC48, and OSC48

Now, for all clamp-open velocity profiles, the QDC module assumes a
linear relationship between clamp velocity and signal output in open loop.