Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 31

Advertising
background image

Overview of Inject, Clamp, and Eject Mode

Chapter 1

1-19

Example 2Ćvalve System for Injection Control

with Clamp and Ejector Position Inputs

With this hydraulic system, the QDC module in the Inject, Clamp, and
Eject mode sends clamp and ejector position data to the PLC-5 processor.

The QDC module can control the following:

closed-loop pressure for injection, pack, hold, and plastication profiles
closed-loop velocity for injection profiles

The PLC-5 processor can control:

clamp and ejector hydraulic directional valves
other hydraulic and machine sequencing

Figure 1.22

2ĆValve System: Injection Control

(Clamp and Ejector Valves Controlled by Ladder Logic)

Tank

Ram (Screw)

A

B

P

T

Tank

Pressure

Control Valve

Flow

Control Valve

Pump

12470ĆI

QDC I/O:

Designations

Input 1

Ram (Screw) Position

Input 2

System Pressure

Input 3

Clamp Position

Input 4

Ejector Position

Output 1

Injection Flow Control

Output 2

Injection Pressure Control

Output 3

Not Used

Output 4

Not Used

Advertising