Select module parameters and i/o ranges – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 46

Advertising
background image

Select Inject , Clamp, and Eject Mode

Required bit 03 = 1

(0 generates a programming error)

Select English = 0

metric = 1

With bit 05 = 04 = 1

Configure the QDC Module's I/O

Chapter 3

3-2

You select module parameters and I/O ranges by setting configuration bits
in control words.

To Configure:

In Control Word: Starting At

ProĆSet 600 Address:

Use this Worksheet:

Module Parameters

MCC02

B34/528

Worksheet 3ĆA

Input Range

MCC03

B34/544

Worksheet 3ĆB

Output Range

MCC04

B34/560

Worksheet 3ĆC

Select module parameters with Worksheet 3-A:

Operating mode of the QDC module to inject, clamp, and eject
Units of measure to English or metric

Select I/O ranges with Worksheets 3-B and 3-C.

Refer to Worksheet 2-A from chapter 2 which you filled out when setting
the QDC module’s jumper plugs. Apply this information to Worksheet 3-B
for input ranges and Worksheet 3-C for output ranges.

Important: Software input/output selections that you are about to make in
MCC03 and MCC04 must match the jumper plug settings for each
respective input and output that you configured in chapter 2.

Important: The QDC module detects loss of sensor at all four inputs
regardless of the input range you select. When detected, the QDC module:

sets status bits SYS08-B00, 01, 02, and 03 for inputs 1, 2, 3, and 4
E-stops the profile in progress
ignores any action execution commands in DYC02

Worksheet 3ĆA

Select Module Parameters

Control Word MCC02ĆBxx

15

14 13 12

11

10

09 08 07 06 05 04 03 02 01 00

ProĆSet 600 Addr. B34/bit

543 542 541 540 539 538 537 536 535 534 533 532 531 530 529 528

Value

0

0

0

0

0

0

0

0

0

0

1

1

1

0

0

Example: If you select Inject, Clamp, and Eject mode with English units:

MCC02 = 00000000 00111000

Select Module Parameters

and I/O Ranges

Advertising