Span Your Valves

Chapter 9

9-48

Span your clamp open velocity (flow) valve(s) for optimum velocity
performance. Do this in three parts:

Confirm critical values
Span your clamp open velocity (flow) valve(s)
Test valve linearity

Important: You may omit the procedure Span your clamp open velocity
(flow) valve(s)
in this section if the recorded valve spanning data from the
manufacturer for velocity control limits FCC45-48, SCC45-48, TCC45-48,
and OSC45-48 (chapter 7) are adequate for your application.

Confirm Critical Values

Important: Confirm that your entries you configuration values (chapter 7)
and profile values (chapter 8) are as follows:

On Worksheet: Confirm Your Configuration:

With These Words or Bits:

ProĆset Addr:

7ĆI, 7ĆJ, 7ĆK, 7ĆL QDC module output to which you connected

your selected velocity control valve

FOC02ĆB02, B01, B00 = your selection

SOC02ĆB02, B01, B00 = your selection

TOC02ĆB02, B01, B00 = your selection

OSC02ĆB02, B01, B00 = your selection

B37/338, 337, 336

B37/402, 401, 400

B37/466, 465, 464

B37/530, 529, 528

Your unselected setĆoutput values for outputs

1Ć4

FOC09Ć12 = your value

SOC09Ć12 = your value

TOC09Ć12 = your value

OSC09Ć12 = your value

N43:305Ć308

N43:365Ć368

N43:425Ć428

N43:485Ć488

All ramping is disabled with zero ramp rates

FOC17Ć20 = FOC25Ć28 = 0

SOC17Ć20 = SOC25Ć28 = 0

TOC17Ć20 = TOC25Ć28 = 0

OSC17Ć20 = OSC25Ć28 = 0

N43:313Ć316

N43:321Ć324

N43:373Ć376

N43:381Ć384

N43:433Ć436

N43:441Ć444

N43:493Ć496

N43:501Ć504

Velocity limits:

Minimum Control Limit

Maximum Control Limit

Selected Velocity Valve, Output for Min

Selected Velocity Valve, Output for Max

FOC45=SOC45=TOC45=OSC45=0

FOC46=SOC46=TOC46=OSC46=sys vel

FOC47=SOC47=TOC47=OSC47=your value

FOC48=SOC48=TOC48=OSC48=your value

N43:341, 401, 461, 521

N43:342, 402, 462, 522

N43:343, 403, 463, 523

N43:344, 404, 464, 524

8ĆE

Select inches/second for velocity units

OPC03ĆB14 = 1

B37/622

Zone overrun - start open slow on overrun

OPC03ĆB11 = 0

B37/619

Logical bridge - start next profile

OPC03ĆB10 = B09 = B08 = 0

B37/618, 617, 616

Expert Response Compensation (ERC) = Off

OPC04ĆB15 - B08 = 1

B37/639Ć632

OpenĆloop control

OPC04ĆB07 - B00 = 1

B37/631Ć624

FOC segment velocities

OPC09, 12, 15 = your values

N43:545, 548, 551

FOC endĆofĆsegment position setpoints

OPC11, 14, 17 = your values

N43:547, 550, 553

Start OSC position setpoint

OPC61 = your value

N43:597

Mold open position setpoint

OPC62 = your value

N43:598

FOC, SOC, TOC, OSC

Profiles -