Install the QDC Module

Chapter 2

2-8

Table 2.B

I/O Terminal Designations

Transducer:

I/O Designation:

Terminal:

Screw position

(see Important below)

Input 1 (+)

(-)

18

17

System pressure

(see ATTENTION below)

Input 2 (+)

(-)

16

15

N/A

Input common

14

Clamp position

(see Important below)

Input 3 (+)

(-)

13

12

Ejector position

(see Important below)

Input 4 (+)

(-)

11

10

Valve 1

Output 1 (+)

Output common

09

08

Valve 2

Output 2 (+)

Output common

07

06

Valve 3

Output 3 (+)

Output common

05

04

Valve 4

Output 4 (+)

Output common

03

02

Not used

01

Important: For the QDC module to operate in the inject, clamp, and eject
mode, you must connect position sensors to these two inputs:

input 1 (screw position)
input 3 (clamp position)

ATTENTION: Your control system may not work as expected
with possibly machine damage if you attempt to control a
pressure profile of a phase (inject, clamp, or eject) not
hydraulically plumbed for pressure control.

Because system pressure may change from one phase to the next, we
recommend that you:

assign pressure control to phases that require pressure profiles

(and are hydraulically plumbed to support it)

place the system pressure sensor accordingly in the hydraulic circuit
configure the remaining phases with velocity profiles