Inc profile pressure valve, 9ć20, Inc profile - pressure valve – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 186: Span your valves chapter 9, Confirm critical values

Advertising
background image

Span Your Valves

Chapter 9

9-20

Span your injection pressure valve for optimum pressure performance.
You do this in four parts:

Confirm critical values
Span your injection pressure valve(s)
Test valve linearity with a pressure vs. time injection profile
Set profile pressure alarms

Important: You may omit the procedure Span your injection pressure
valve(s)
in this section if the recorded valve spanning data from the
manufacturer in pressure control limits INC41-44 (chapter 7) is adequate
for your application.

Confirm Critical Values

Important: Confirm that all entries you made for configuration values
(chapter 7) and profile values (chapter 8) are as follows:

On Worksheet

Confirm Your Configuration

With These Words or Bits

ProĆSet Addr.

7ĆE, 7ĆG

QDC module output to which you connected

your pressure control valve

INC02ĆB06, B05, B04

B38/20, 21, 22

SetĆoutput values for unselected valves

INC09Ć12 = your values

N44:5, 6, 7, 8

All ramping is disabled with zero ramp rates

INC17Ć20 = 0

INC25Ć28 = 0

N44:13Ć16

N44:21Ć24

Pressure limits:

Minimum Pressure Control Limit

Maximum Pressure Control Limit

Selected Pressure Valve, Output for Min

Selected Pressure Valve, Output for Max

INC41 = 0

INC42 = system pressure

INC43 = your value

INC44 = your value

N44:37

N44:38

N44:39

N44:40

EndĆofĆprofile setĆoutput values

HDC33Ć36 for zero output

N44:209Ć212

8ĆB, 8ĆC

Pressure vs Time algorithm

IPC03ĆB01 = B00 = 1

B38/96Ć97

OpenĆloop control

IPC04ĆB03 = B02 = B01 = B00 = 1

B38/112Ć115

Expert Response Compensation (ERC) = Off

IPC04ĆB11 = B10 = B09 = B08 = 1

B38/120Ć123

Pressure setpoints

IPC10,14,18,22,26,30,34,38,42,46,50

all equal to oneĆhalf system pressure

start @ N44:66

end @ N44:106

Time setpoints

IPC12,16,20,24,28,32,36,40,44,48

all equal to 1 second (100)

start @ N44:68

end @ N44:104

Transition setpoints

Time limit

Ram (screw) position

Ram (screw) pressure

Cavity pressure

Minimum position for pressure transition

IPC60 = 10 seconds (1000)

IPC61 = zero to inhibit

IPC62 = zero to inhibit

IPC63 = zero to inhibit

IPC64 = zero to inhibit

N44:116

N44:117

N44:118

N44:119

N44:120

Logical bridge to stop and set outputs

HPC03ĆB08 = 1

B38/296

If these are not your current values, we suggest that you correct them now
using the download procedure discussed in chapter 4.

INC Profile -

Pressure Valve

Advertising