We refer to these procedures throughout this manual whenever you must:

enter data table values
download data blocks

Enter Values into Your PLCĆ Data Table

With your programming terminal, enter worksheet values into your PLC-5
data table as follows:

1.

Switch the PLC-5 processor to

PROGRAM

mode.

2.

Display your PLC-5 data table

3.

Locate the data files for storing the subject block as specified on
individual worksheets.

4.

Enter the value for each word and bit.

When you set bits in words prefixed with file identifier B (example: B34),
the PLC-5 processor automatically switches the radix to binary format.

Download Data Blocks

We define the following data words and functions used in the procedure to
download data blocks.

This Word:

At Address:

Provides this Function:

DYC61

N40:173

Requests that the QDC module return an error if it

finds one in the designated data block. The QDC

module reports the error in SYS61 and SYS62.

SYS61

N40:213

The QDC module reports the ID of the data block

containing the error (identified in SYS62). This word

will match a nonĆzero DYC61.

SYS62

N40:214

The QDC module reports the error code in this

word. This error code relates to the data block

whose ID is reported in SYS61.

The following steps outline the procedure to download data blocks from
the PLC-5 data table to the QDC module.

Important: The exception to this procedure is the MCC block that has its
own download procedure already outlined in chapter 3. The QDC module
must store a valid MCC block before you can use the following procedure.

1.

For the block you want to download (subject block), get its ID
number from Table 4.A and enter it into DYC61.

Enter Data Table Values

and Download Data Blocks