Set module jumpers – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 34

Advertising
background image

Install the QDC Module

Chapter 2

2-2

Before installing the QDC module, you must select with jumper plugs the
I/O ranges that you recorded on Worksheet 2-A

Access and Position the Jumpers

Access the jumper plugs and set them as follows:

ATTENTION: To avoid damage to internal circuits, observe
handling precautions and rid yourself of any electrostatic
charge. Use an anti-static work station when setting jumpers.

1.

Remove the label-side cover plate by removing the four screws.

2.

Remove the circuit board from the module housing by removing the
two screws located center-front at the swingarm catch.

3.

Carefully turn over the circuit board so it is oriented as in figure 2.1.
Handle it by the edges to avoid touching conductors or components.

4.

Use figure 2.1 to locate the jumpers.

5.

Set the jumpers according to Table 2.A (next page) using

your I/O ranges from Worksheet 2-A
needle-nose pliers.

6.

After setting the jumpers, carefully re-assemble the module with steps
3, 2, and 1.

Set Module Jumpers

Advertising