Record Your Final Values Here

Configure the QDC Module's I/O

Chapter 3

3-9

Worksheet 3ĆE

Final SensorĆconfiguration Values

Input

Line

Control Word

ProĆSet 600 Addr. Value

Description

1

1

MCC09

N40:5

0

Minimum Screw Position

1

2

MCC10

N40:6

Maximum Screw Position

1

3

MCC11

N40:7

Analog Signal @ Min Screw Position

2

4

MCC12

N40:8

Analog Signal @ Max Screw Position

2

2

5

MCC57

N40:53

0

Minimum System Pressure

3

6

MCC58

N40:54

Maximum System Pressure

3

7

MCC59

N40:55

Analog Signal @ Min System Pressure

2

8

MCC60

N40:56

Analog Signal @ Max System Pressure

2

3

9

MCC23

N40:19

0

Minimum Clamp Position

1

10

MCC24

N40:20

Maximum Clamp Position

1

11

MCC25

N40:21

Analog Signal @ Min Clamp Position

2

12

MCC26

N40:22

Analog Signal @ Max Clamp Position

2

4

13

MCC31

N40:27

0

Minimum Ejector Position

1

14

MCC32

N40:28

Maximum Ejector Position

1

15

MCC33

N40:29

Analog Signal @ Min Ejector Position

2

16

MCC34

N40:30

Analog Signal @ Max Ejector Position

2

1

Incremental Distance

2

Input Signal Range

3

Pressure

00.00 to 99.99in

00.00 to 10.00VDC or

0000 to 9999 PSI

000.0 to 999.9mm

01.00 to 05.00VDC or

000.0 to 999.9 Bar

04.00 to 20.00MADC

Determine Values for Ram (Screw) Position Sensor

ATTENTION: Incorrect values entered in DYC09-12 may
result in rapid ram (screw) motion and potential damage to your
barrel and seals of your injection cylinder.

To complete the configuration for your ram (screw) position sensor, do the
following and enter the results on Worksheet 3-E:

1.

Move the ram (screw) forward until it reaches its mechanical stop at
the nozzle end. This is the zero position.

2.

Remove ram (screw) pressure and/or flow to stop movement.