Download mcc parameters to the qdc module, Configure the qdc module's i/o chapter 3, Enter mcc parameters into your plcć5 data table – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 49

Advertising
background image

Record Your Initial Values Here

Configure the QDC Module's I/O

Chapter 3

3-5

Worksheet 3ĆD

Determine Initial SensorĆconfiguration Values

Input

Line

Control Word

ProĆSet 600 Addr. Value

Description

1

1

MCC09

N40:5

0

Minimum Screw Position

1

2

MCC10

N40:6

Maximum Screw Position

1

3

MCC11

N40:7

Analog Signal @ Min Screw Position

2

4

MCC12

N40:8

Analog Signal @ Max Screw Position

2

2

5

MCC57

N40:53

0

Minimum System Pressure

3

6

MCC58

N40:54

Maximum System Pressure

3

7

MCC59

N40:55

Analog Signal @ Min System Pressure

2

8

MCC60

N40:56

Analog Signal @ Max System Pressure

2

3

9

MCC23

N40:19

0

Minimum Clamp Position

1

10

MCC24

N40:20

Maximum Clamp Position

1

11

MCC25

N40:21

Analog Signal @ Min Clamp Position

2

12

MCC26

N40.22

Analog Signal @ Max Clamp Position

2

4

13

MCC31

N40:27

0

Minimum Ejector Position

1

14

MCC32

N40:28

Maximum Ejector Position

1

15

MCC33

N40:29

Analog Signal @ Min Ejector Position

2

16

MCC34

N40:30

Analog Signal @ Max Ejector Position

2

1

Incremental Distance

2

Input Signal Range

3

Pressure

00.00 to 99.99in 00.00 to 10.00VDC or

0000 to 9999 PSI

000.0 to 999.9mm 01.00 to 05.00VDC or 000.0 to 999.9 Bar

04.00 to 20.00MADC

Use this download procedure now and later in this chapter. The procedure
requires you to complete the following general steps:

enter MCC parameters into the PLC-5 data table
download them to the QDC module (with PLC-5 processor in run mode)
correct any programming errors

Next, we describe the general steps.

Enter MCC Parameters into Your PLCĆ5 Data Table

With your programming terminal, enter values from Worksheet 3-A thru
4-D into your PLC-5 data table as follows:

1. Switch the PLC-5 processor to

PROGRAM

mode.

2. Display your PLC-5 data table.

Download MCC Parameters

to the QDC Module

Advertising