Span Your Valves

Chapter 9

9-39

3.

While observing actual pressure in SYS26 (N40:178) and the output
in SYS41-44 (N40:193-196) that corresponds to the selected
plastication valve, run a plastication backpressure vs. position profile.
Do this by toggling DYC04-B08 (B34/408) from 0 to 1 to 0.

4.

With your programming terminal, record:

maximum profile backpressure displayed in SYS26 (N40:178)

Record here a) ___________

%-output signal in SYS41-44 (N40:193-196) corresponding to the

ram (screw) plastication valve
Record here b)___________

5.

Compute the signal level required for the Selected Pressure Valve,
Output for Maximum PLC44 as follows:

PLC44 =

Max desired

backpressure

x

Observed %Ćsignal output in SYS41Ć44 that

corresponds to the ram plastication valve

Observed Pressure in SYS26

Important: If your valve is reverse acting, apply the algebraic sign (–) of
value b correctly when computing PLC44.

PLC44 =

x

PPC10

Your recorded value b

Your recorded value a

PLC44 = _______________ For example, 1000 for 10%

6.

Enter new values into the PLC data table:

- value from step 5 into PLC44 (N44:400)

- maximum desired backpressure PPC10 from step 5 into PLC42

(N44:398)

7.

Download the PLC block to the QDC module.

Important: If downloading from your programming terminal, download
PLC followed by PPC with download bits B21/13 and 14 (chapter 4).

8.

Run an open-loop backpressure vs. position profile. Do this by
toggling DYC02-B08 (B34/408) from 0 to 1 to 0.

Advertising