Span Your Valves

Chapter 9

9-21

Span Your Injection Pressure Valve

Span your injection valve for smooth operation at highest desired pressure.
Do this in the following procedure by finding the optimum values for:

Minimum Pressure Control Limit INC41 (N44:37)
Maximum Pressure Control Limit INC42 (N44:38)
Selected Pressure Valve, Output for Minimum INC43 (N44:39)
Selected Pressure Valve, Output for Maximum INC44 (N44:40)

Important: If PanelView is operational for injection profiles, use it to:

observe actuals
change and download setpoints
run profiles

Important: We suggest that you read this procedure before starting.

ATTENTION: As with any machine start-up, install a test
mold. Programming errors, configuration errors, or hydraulic
problems could lead to personal injury and/or machine damage.

ATTENTION: Be sure all machine guards and shields are in
place before proceeding to guard against personal injury.

1.

Manually jog your ram (screw) to the mold-end position so you can
exert maximum pressure against the nozzle tip.

2.

Align all other machine hydraulics to simulate injection: enable
pumps and align valves to their normal injection state.

3.

Copy initial values INC09-12 (N44:5-8) into DYC09-12
(N40:121-124) of your PLC-5 data table with this exception:

Important: Enter a value corresponding to zero pressure into the word
DYC09-12 (N40:121-124) for output 1, 2, 3, or 4 that drives the selected
clamp pressure valve.

ATTENTION: A value of 0 does not always correspond to zero
pressure or flow. For example, a bi-directional valve requires a
set-output value of 50% (5000) to obtain 0 PSI. Valve spools or
amplifier electronics may also allow pressure or flow at 0 volts.