Load Initial Profile Setpoints
Chapter 8
8-42
Block Identifier
(EPC01)
Bits 07-00 of this word identify it as the first word in a series used to
define the ejector profile. Pro-set 600 sets these bits to 00011000.
We recorded this value on Worksheet 8-F.
Ejector Forward Dwell
(EPC03
)
Forward dwell stops the ejector in its full advance position to let a robot
remove a part when ejectors are fully extended.
- BIT 15 selects when the QDC module starts its internal ejector
forward dwell timer:
0 = after final advance stroke
1 = after initial advance stroke
We recorded the value of 0 to start forward dwell on final advance
stroke.
Velocity Units
(EPC03
)
- BIT 14 selects units of measure for velocity values.
0 = Percent velocity
1 = Inches or millimeters per second
We recorded the value of 1 for units per second on Worksheet 8-F.
Type of Ejector Strokes
(EPC03)
- BIT 13 selects the type of intermediate ejector strokes, if you select
multiple strokes (EPC64 greater than one).
0 = All ejector strokes are full strokes
1 = Intermediate ejector strokes are tip strokes
We recorded the value of 0 for full strokes on Worksheet 8-F.
Determine Bit Selections
for Worksheet 8ĆF