Determine bit selections for worksheet 8-f, 8ć42 – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 159

Advertising
background image

Load Initial Profile Setpoints

Chapter 8

8-42

Block Identifier

(EPC01)
Bits 07-00 of this word identify it as the first word in a series used to
define the ejector profile. Pro-set 600 sets these bits to 00011000.

We recorded this value on Worksheet 8-F.

Ejector Forward Dwell

(EPC03

)

Forward dwell stops the ejector in its full advance position to let a robot
remove a part when ejectors are fully extended.

- BIT 15 selects when the QDC module starts its internal ejector

forward dwell timer:

0 = after final advance stroke
1 = after initial advance stroke

We recorded the value of 0 to start forward dwell on final advance
stroke.

Velocity Units

(EPC03

)

- BIT 14 selects units of measure for velocity values.

0 = Percent velocity
1 = Inches or millimeters per second

We recorded the value of 1 for units per second on Worksheet 8-F.

Type of Ejector Strokes

(EPC03)

- BIT 13 selects the type of intermediate ejector strokes, if you select

multiple strokes (EPC64 greater than one).

0 = All ejector strokes are full strokes
1 = Intermediate ejector strokes are tip strokes

We recorded the value of 0 for full strokes on Worksheet 8-F.

Determine Bit Selections

for Worksheet 8ĆF

Advertising