Span your valves chapter 9 – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual
Page 198

Span Your Valves
Chapter 9
9-32
On
Worksheet
Confirm Your Configuration
With These Words or Bits
for Hold Pressure
ProĆSet Addr
8ĆC
Pressure vs Time algorithm
for Pack and Hold
HPC03ĆB02 = B00 = 0
B38/288, 290
Logical bridge to stop and set outputs before:
preĆdecompression
plastication
HPC03ĆB08 = 1
HPC03ĆB09 = 1
B38/296
B38/297
OpenĆloop control
HPC04ĆB03, B02, B01, B00 = 1
B38/304Ć307
Expert Response Compensation (ERC) = Off
HPC04ĆB11, B10, B09, B08 = 1
B38/312Ć315
Pressure setpoints
HPC10,13,16,19,22,27,30,33,36,
39 all equal full injection pressure
start @ N44:246
end @ N44:275
Time setpoints
HPC11,14,17,20,23,28,31,34,37
40 all equal to 1 second (100)
start @ N44:247
end @ N44:276
If these are not your current values, we suggest that you correct them now
and download them using the download procedure discussed in chapter 4.
Before proceeding, observe these warnings:
ATTENTION: As with any machine start-up, install a test
mold. Programming errors, configuration errors, or hydraulic
problems could lead to personal injury and/or machine damage.
ATTENTION: Be sure all machine guards and shields are in
place before proceeding to guard against personal injury.