background image

Load Initial Profile Setpoints

Chapter 8

8-9

4. Record your FCC end-of-segment position setpoints for CPC11, 14,

and 17 on Worksheet 8-A.

We recorded zero for the remaining position setpoints on Worksheet 8-A.

The valve spanning procedures in chapter 9 require these initial values.
We help you select correct final values for your application in chapter 10.
For additional information, refer to Section 3 of the Plastic Molding
Module Reference Manual (publication 1771-6.5.88).

TonnageĆcomplete Pressure Setpoint

(CPC63)
The QDC module compares clamp pressure with this value, and sets status
bit SYS03-B02 when clamp pressure equals or exceeds this value.

We recorded zero for the tonnage watchdog timer preset.

The valve spanning procedures in chapter 9 require this initial value. We
help you select correct final values for your application in chapter 10. For
additional information, refer to Section 3 of the Plastic Molding Module
Reference Manual (publication 1771-6.5.88).

After you determine initial values and record them on Worksheet 8-A, you
are ready to proceed. Refer to procedures in chapter 4 if necessary.

Important: Be sure that you do not alter any setpoints, and that you enter
each and every setpoint exactly as on the worksheet.

1. Enter all worksheet values into your PLC-5 data table.

2. Download command blocks to the QDC module. We repeat the CPC

block download data.

Block to

Download:

ProĆSet 600

Block ID:

Download

Command Bit:

Companion

Block:

CPC

07

B21/6

none

3. Check SYS61 and SYS62 for programming error. Correct as needed.

Enter and Download Your