Plc profile - pressure valve, 9ć37, Span your valves chapter 9 – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 203: Confirm critical values

Advertising
background image

Span Your Valves

Chapter 9

9-37

We recommend that you span your plastication pressure valve for optimum
plastication performance in four parts:

Confirm critical values
Span your plastication pressure valve
Test valve linearity with a plastication backpressure vs. position profile
Set the profile pressure alarm

Important: You may omit the procedure Span your plastication pressure
valve
in this section if the recorded valve spanning data from the
manufacturer in pressure control limits PLC41-44 (chapter 7) are adequate
for your application.

Confirm Critical Values

Important: Confirm that all entries you made for configuration values
(chapter 7) and profile values (chapter 8) are as follows:

On Worksheet Confirm Your Configuration

With These Words or Bits

ProĆSet Addr

7ĆH

QDC module output to which you connected

your plastication pressure control valve

PLC02ĆB06, B05, B04

B38/404Ć406

SetĆoutput values for unselected valves

PLC09Ć12 = your values

N44:365Ć368

All ramping is disabled with zero ramp rates

PLC17Ć20 = 0

PLC25Ć28 = 0

N44:373Ć376

N44:381Ć384

EndĆofĆprofile SetĆoutput values

PLC33Ć36 for zero output

N44:389Ć392

Pressure limits:

Minimum Pressure Control Limit

Maximum Pressure Control Limit

Selected Pressure Valve, Output for Min

Selected Pressure Valve, Output for Max

PLC41 = 0

PLC42 = max attainable backpressure

PLC43 = your value

PLC44 = your value

N44:397

N44:398

N44:399

N44:400

8ĆD

Backpressure vs Position algorithm

PPC03ĆB00 = 0

B38/480

Logical bridge to stop and set outputs before

postĆdecompression

PPC03ĆB08 = 1

B38/488

OpenĆloop control

PPC04ĆB01 = B00 = 1

B38/496, 497

Expert Response Compensation (ERC) = Off

PPC04ĆB09 = B08 = 1

B38/504, 505

Backpressure setpoints

PPC10,14, 18, 22, 26, 30, 34, 38, 42,

46, 50 all equal to max desired

backpressure

start @ N44:426

end @ N44:466

Position setpoints

PPC11,15,19,23,27,31,35,39,43,47

equal segments over shot size

start @ N44:427

end @ N44:463

Shot size

PPC62 = typical for your machine

N44:478

If these are not your current values, we suggest that you correct them now
and download them using the download procedure discussed in chapter 4.