Load Initial Profile Setpoints

Chapter 8

8-17

The valve spanning procedures in chapter 9 require these initial values.
We help you select correct final values for your application in chapter 10.
For additional information, refer to Section 3 of the Plastic Molding
Module Reference Manual (publication 1771-6.5.88).

Transition Setpoints

(IPC60, 61, 62, and 64)
Use these words when configuring the type of transition from injection to
the pack (or hold) profile. The QDC module starts the transition when it
detects the first of the following conditions that you enable with a non-zero
setpoint. You may enable one or more of the following:

- IPC60 determines the transition time limit. The QDC module

immediately terminates the injection profile and begins the pack (or
hold) profile if total injection-profile execution time equals or
exceeds the non-zero entry in this word.

We recorded 10 seconds (1000) for this setpoint on Worksheet 8-B.

- IPC61 determines the ram (screw) position for transition. The QDC

module immediately terminates the injection profile and begins the
pack (or hold) profile if the ram (screw) position is less than or equal
to the non-zero entry in this word. Use a position equal to or just
beyond top-of-cushion position PPC61 measured from the mold end.

We recorded zero on Worksheet 8-B to inhibit a position transition.

- IPC62 determines the ram (screw) pressure for transition. The QDC

module immediately terminates the injection profile and begins the
pack (or hold) profile if both occur:

ram (screw) position is less than or equal to any non-zero entry in

INC64, start of zone for pressure transition

ram (screw) pressure equals or exceeds the non-zero entry in this

word. Typically, you use a setpoint below mold-flash pressure.

We recorded zero on Worksheet 8-B to inhibit pressure transition.

- IPC64 determines the start of zone in which the QDC module allows

pressure transitions. A non-zero value measured from the mold end
forces the QDC module NOT to transition on pressure until the ram
(screw) reaches this position. A zero setpoint forces the QDC
module to use any non-zero pressure setpoint in IPC62 over the entire
injection profile.

We recorded zero on Worksheet 8-B to inhibit this function.

The valve spanning procedures in chapter 9 require these initial values.
We help you select correct final values for your application in chapter 10.
For additional information, refer to Section 3 of the Plastic Molding
Module Reference Manual (publication 1771-6.5.88).