Select Command and Status Bits to

Sequence Machine Operation

Chapter 6

6-2

Use the following tables to select command and status bits when writing
ladder logic to control manual functions and machine sequencing.

Table 6.A

Command and Status Bits for Manual Control

To Initiate this action:

Set this bit:

ProĆSet

B34/xx:

The QDC sets this bit

during execution:

ProĆSet

B34/xx:

Direct SetĆoutput

DYC01ĆB08

392

SYS01ĆB08

08

Unassigned #1 Jog

DYC01ĆB09

393

SYS01ĆB09

09

Ram (screw) Forward Jog DYC01ĆB10

394

SYS01ĆB10

10

Ram (screw) Reverse Jog DYC01ĆB11

395

SYS01ĆB11

11

Clamp Forward Jog

DYC01ĆB12

396

SYS01ĆB12

12

Clamp Reverse Jog

DYC01ĆB13

397

SYS01ĆB13

13

Ejector Advance Jog

DYC01ĆB14

398

SYS01ĆB14

14

Ejector Retract Jog

DYC01ĆB15

399

SYS01ĆB15

15

Stop

DYC02ĆB15

415

SYS02ĆB15

31

Table 6.B

Command Bits for Starting Profiles

To initiate this

Profile/Movement:

Toggle this

bit in DYC02:

ProĆSet

B34/xx:

If this bit is

Reset:

ProĆSet

Address:

The Profile/Movement in column 1

starts automatically after:

1st Clamp Close

00

400

---

---

---

2nd Clamp Close

01

401

CPC03ĆB08

B37/296

1st Clamp Close

3rd Clamp Close

02

402

CPC03ĆB09

B37/297

2nd Clamp Close

Low Pressure Close

03

403

CPC03ĆB10

B37/298

3rd Clamp Close

Injection

04

404

1

---

---

---

Pack

05

405

1

---

---

Injection

Hold

06

406

1

---

---

Pack

PreĆdecompression

07

407

HPC03ĆB08

B38/296

Hold

Plastication

08

408

HPC03ĆB09

B38/297

PreĆdecompression

PostĆdecompression

09

409

PPC03ĆB08

B38/488

Plastication

1st Clamp Open

10

410

---

---

---

2nd Clamp Open

11

411

OPC03ĆB08

B37/616

1st Clamp Open

3rd Clamp Open

12

412

OPC03ĆB09

B37/617

2nd Clamp Open

Clamp Open Slow

13

413

OPC03ĆB10

B37/618

3rd Clamp Open

1st Ejector Advance

14

414

EPC03ĆB08

B39/168

On Clamp Position During Open

Ejector Continue

15

415

EPC03ĆB12

B39/172

Previous Ejector Stroke

1

Injection, Pack, and Hold are always linked as one profile.