Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 268

Advertising
background image

Select Input 1 (Screw Position) Range with bits 01, 00

Select Input 2 (Screw Pressure) Range with bits 03, 02

Select Input 3 (Clamp Position) Range with bits 05, 04

Select Input 4 (Clamp Pressure) Range with bits 07, 06

Input Range

0 - 10V dc

0

0

1 - 5V dc

0

1

4 - 20 mA

1

0

Not connected

1

1

Select Output 1 Range with bits 01, 00

Select Output 2 Range with bits 03, 02

Select Output 3 Range with bits 05, 04

Select Output 4 Range with bits 07, 06

Output Range

-10 to +10V dc

0

0

0 to +10V dc

0

1

4 to 20 mA

1

0

Not connected

1

1

Blank Worksheets

Appendix A

A-2

Worksheet 4ĆB
Selecting Input Ranges for your Sensors

Control Word MCC03ĆBxx

15

14 13 12 11

10

09 08 07 06 05 04 03 02 01 00

ProĆSet 600 Addr. B34/bit

559 558 557 556 555 554 553 552 551 550 549 548 547 546 545 544

Value

1

1

1

1

1

1

1

1

Example: If you select an input range of 4-20 mA for all four inputs:

MCC03 = 11111111 10101010.

Important: Software input selections must match the jumper settings for
each respective input.

Worksheet 4ĆC
Selecting Output Ranges for your Valves

Control Word MCC04ĆBxx

15

14 13 12 11

10

09 08 07 06 05 04 03 02 01 00

ProĆSet 600 Addr. B34/bit

575 574 573 572 571 570 569 568 567 566 565 564 563 562 561 560

Value

1

1

1

1

1

1

1

1

Example: If you select 0-10V dc for all four output ranges:

MCC04 = 11111111 01010101.

Important: Software output selections must match the jumper settings for
each respective output.

Advertising