Span Your Valves

Chapter 9

9-58

Span your ejector velocity (flow) valve(s) for optimum velocity
performance. Do this in three parts:

Confirm critical values
Span your ejector velocity (flow) valve(s)
Test valve linearity with an ejector velocity profile

Important: Omit the procedure Span your ejector velocity (flow) valve(s)
in this section if the recorded manufacturer’s valve spanning data for
pressure control limits EAC45-48 and ERC45-48 are adequate.

Confirm Critical Values

Important: Confirm that all your entries for configuration values (chapter
7) and profile values (chapter 8) are as follows:

On Worksheet: Confirm Your Configuration:

With These Words or Bits:

ProĆset Addr:

7ĆM, 7ĆN

QDC module output to which you connected

your selected velocity control valve

EAC02ĆB02, B01, B00 = your selection

ERC02ĆB02, B01, B00 = your selection

B39/18, 17, 16

B39/82, 81, 80

Unselected setĆoutput values for outputs 1Ć4

EAC09Ć12 = ERC09Ć12 = your value

N45:05Ć08, 65Ć68

All ramping is disabled with zero ramp rates

EAC17Ć20, 25Ć28 = ERC17Ć20, 25Ć28 =

0

N45:13Ć16, 21Ć24, 73Ć76, 81Ć84

Velocity limits:

Minimum Control Limit

Maximum Control Limit

Selected Velocity Valve, Output for Min

Selected Velocity Valve, Output for Max

EAC45 = ERC45 = 0

EAC46 = ERC46 = max velocity spec.

EAC47 = ERC47 = your value

EAC48 = ERC48 = your value

N45:41, 101

N45:42, 102

N45:43, 103

N45:44, 104

8ĆF

Forward Dwell - apply after final stroke

EPC03ĆB15 = 0

B39/175

Velocity Units - inches/second

EPC03ĆB14 = 1

B39/174

Type of stroke - all full strokes

EPC03ĆB13 = 0

B39/173

Continue or stop/notify - your selection

EPC03ĆB12

B39/172

Ejector profile On/Off - profile On

EPC03ĆB09 = 0

B39/169

Logical bridge - start on command from PLC

EPC03ĆB08 = 1

B39/168

Expert Response Compensation (ERC) = Off

EPC04ĆB09 = B08 = 1

B39/185Ć184

OpenĆloop control

EPC04ĆB01 = B00 = 1

B39/177Ć176

EPC endĆofĆsegment position setpoints

EPC11, 14, 23, 29, 35, 38 = zero

N45:127,130,139,145,151,154

Ejector forward dwell timer preset

EPC57 = zero

N45:173

Ejector full advance position setpoint

EPC59 = your value

N45:175

Ejector full retract position setpoint

EPC60 = your value

N45:176

Clamp position for start ejector profile

EPC61 = value in OPC62

N45:177

Clamp position for ejector inhibit

EPC62 = your value

N45:178

Ejector position for clamp close enable

EPC63 = your value

N45:179

Ejector strokes required

EPC64 = one

N45:180

If these are not your current values, we suggest that you correct them now