Install the qdc module chapter 2 – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual
Page 36
![background image](/manuals/579548/36/background.png)
Install the QDC Module
Chapter 2
2-4
Table 2.A
Jumper Settings
Jumper:
Function:
Setting:
E1
Run/Calibrate
Run = left
1
Calibrate = right
E5
I/O Density
Standard = top
1
Do not use bottom position
E6
E7
E8
E9
Input 1 (Screw position)
Input 2 (System pressure)
Input 3 (Clamp position)
Input 4 (Ejector position)
Current = left
Voltage = right
1
E10
E14
E13
E17
Output 1 (Valve 1)
Output 2 (Valve 2)
Output 3 (Valve 3)
Output 4 (Valve 4)
Current = top
Voltage = bottom
1
E11
E12
E15
E16
Output 1 (Valve 1)
Output 2 (Valve 2)
Output 3 (Valve 3)
Output 4 (Valve 4)
-10 to +10V dc = top
0 to +10V dc or
4 to 20mA = bottom
1
1
Factory Defaults
Important: If you select current output with jumpers E10, E14, E13, E17,
then you must select 4 to 20mA with jumpers E11, E12, E15, E16.
ATTENTION: If an output is not used, set its jumper (E11,
E12, E15, or E16) to 0 - 10V dc (bottom position). Otherwise,
setting the jumper for –10 to +10V dc could cause the QH
module to output –10V dc on that channel (a hazard): because
when the system is stopped or when a system reset occurs, all
outputs are forced to 0% but 0% output = –10V dc in this
example (see graph).
% Output Requested
Output V
oltage
-10
-8
-5
-3
0
3
5
8
10
0
10 20 30 40 50 60 70 80 90 100