Install the QDC Module

Chapter 2

2-4

Table 2.A

Jumper Settings

Jumper:

Function:

Setting:

E1

Run/Calibrate

Run = left

1

Calibrate = right

E5

I/O Density

Standard = top

1

Do not use bottom position

E6

E7

E8

E9

Input 1 (Screw position)

Input 2 (System pressure)

Input 3 (Clamp position)

Input 4 (Ejector position)

Current = left

Voltage = right

1

E10

E14

E13

E17

Output 1 (Valve 1)

Output 2 (Valve 2)

Output 3 (Valve 3)

Output 4 (Valve 4)

Current = top

Voltage = bottom

1

E11

E12

E15

E16

Output 1 (Valve 1)

Output 2 (Valve 2)

Output 3 (Valve 3)

Output 4 (Valve 4)

-10 to +10V dc = top

0 to +10V dc or

4 to 20mA = bottom

1

1

Factory Defaults

Important: If you select current output with jumpers E10, E14, E13, E17,
then you must select 4 to 20mA with jumpers E11, E12, E15, E16.

ATTENTION: If an output is not used, set its jumper (E11,
E12, E15, or E16) to 0 - 10V dc (bottom position). Otherwise,
setting the jumper for –10 to +10V dc could cause the QH
module to output –10V dc on that channel (a hazard): because
when the system is stopped or when a system reset occurs, all
outputs are forced to 0% but 0% output = –10V dc in this
example (see graph).

% Output Requested

Output V

oltage

-10

-8

-5

-3

0

3

5

8

10

0

10 20 30 40 50 60 70 80 90 100

Advertising