Load Initial Profile Setpoints

Chapter 8

8-38

FOC Seg 3

(OPC17)

(OPC61)

FOC Seg 2

(OPC14)

Mold Safe

(CPC62)

FOC Seg 1

(OPC11)

Clamp Travel Range

Fully Open

(OPC62)

zero

4. Record your FOC end-of-segment position setpoints for OPC11, 14,

and 17 on Worksheet 8-E.

We recorded zero for the remaining position setpoints on Worksheet 8-E.

The valve spanning procedures in chapter 9 require these initial values.
We help you select correct final values for your application in chapter 10.
for additional information, refer to Section 3 of the Plastic Molding
Module Reference Manual (publication 1771-6.5.88).

Mold Open Dwell Timer Preset

(OPC63)
The QDC module starts its internal mold open dwell timer according to
how you set OPC03-B15.

We recorded zero for the mold open dwell timer preset.

The valve spanning procedures in chapter 9 require this initial value. We
help you select correct final values for your application in chapter 10. For
additional information, refer to Section 3 of the Plastic Molding Module
Reference Manual (publication 1771-6.5.88).

After you determine initial values and record them on Worksheet 8-E, you
are ready to proceed. Refer to procedures in chapter 4 if necessary.

Important: Be sure that you do not alter any setpoints, and that you enter
each and every setpoint exactly as on the worksheet.

1. Enter all worksheet values into your PLC-5 data table.

2. Download command blocks to the QDC module. We repeat the OPC

block download data.

Block to

Download:

ProĆSet 600

Block ID:

Download

Command Bit:

Companion

Block:

OPC

21

B21/20

none

3. Check SYS61 and SYS62 for programming errors. Correct as needed.