1ć16 – Rockwell Automation 1771-QDC, D17716.5.93(Passport) PLASTIC MOLDING MODULE User Manual

Page 28

Advertising
background image

Overview of Inject, Clamp, and Eject Mode

Chapter 1

1-16

Because system pressure may change from one phase to the next, we
recommend that you:

assign pressure control to phases that require pressure profiles

(and are hydraulically plumbed to support it)

place the system pressure sensor accordingly in the hydraulic circuit
configure the remaining phases with velocity profiles

We define open-loop pressure control as when the QDC module controls
phase pressure without input from the system pressure sensor. For example:
when the system pressure sensor monitors the clamp for closed-loop pressure
control, the QDC module can control:

ram (screw) pressure for pack, hold, and plastication in open loop
ejector velocity in closed- or open-loop using a position sensor

For example:

For this Phase

The QDC Module Can Control it With

clamp close and open

closedĆloop pressure

injection

openĆloop pressureĆlimited velocity

pack/hold

openĆloop pressure

plastication

openĆloop pressure

ejector advance and retract

velocity

In general:

If your system pressure sensor

reads pressure for only ONE of

these modes:

Then you must control the other modes by either of:

1. closedĆ or openĆloop velocity

2. openĆloop pressure

inject

clamp, eject

clamp

inject , eject

eject

inject, clamp

We illustrate three examples of hydraulic circuits compatible with the QDC
module in the inject, clamp, and eject mode:

4-valve system with system pressure sensor
3-valve system with ram (screw) pressure sensor
2-valve system for inject phase with clamp and ejector position inputs

(clamp and ejector direction solenoid valves controlled by ladder logic)

Example Hydraulic Circuits

for the Inject, Clamp, and

Eject Mode

Advertising