Configure the QDC Module's I/O

Chapter 3

3-6

3.

Locate the data file for storing the MCC block. PLC-5 data table
word addresses are listed on the worksheets.

4.

Enter the value for each word and bit.

When you enter bit selections in words prefixed with file identifier B
(example: B34), the PLC-5 processor automatically switches the radix to
binary format so you can conveniently enter binary data.

Download MCC Parameters

To download the MCC block to the QDC module, switch the PLC-5
processor from

PROGRAM

mode to

RUN

mode. Pro-Set 600 software

downloads the MCC to the QDC module for you.

Important: You can verify that the MCC block was successfully down-
loaded or you made a programming error by evaluating the following
words that Pro-Set 600 software continuously reports to the PLC-5
processor.

If:

And:

Then:

SYS01ĆB08 = 1

(B34/8)

N/A

QDC module accepted a valid MCC.

SYS19ĆB00 = 1

(B34/288)

SYS61 = 1

(ID code for MCC block

stored in N40:213)

You made a programming error in MCC.

Read the error code in SYS62 (N40:214), and

look up the error in Section 2 of the Plastic

Molding Module Reference Manual (pub. no.

1771Ć6.5.88).

Important: Pro-Set 600 software downloads all command blocks when
your PLC-5 processor enters run mode and after a valid MCC is accepted.
All programming errors reported in SYS62 (N40:214) are referenced to the
MCC until SYS01-B08 (B34/08) equals zero.

Correct Any DataĆentry Errors

Upon receipt of MCC block, the QDC module tests data for data-entry
errors, such as a value out of range. When it detects an error, The QDC
module halts operation until you correct the error. For a complete list of
error codes to help you correct errors, refer to Section 2 of the Plastic
Molding Module Reference Manual, publication 1771-6.5.88.

You must correct errors by entering the changed configuration values into
your PLC-5 data table and downloading the new values to the QDC
module as outlined above. Pro-Set 600 software continues to attempt to
download the MCC block to the QDC module until an MCC is accepted
and the QDC module returns SYS01-B08 (B34/08) equal to 1.