Preface
P-4
Status Blocks
Status blocks report current status of molding-machine operation. They
are returned from the QDC module to the PLC-5 processor by means of
block transfer read (BTR) instructions in software ladder logic. Status
block abbreviations are:
Acronym:
Description:
SYS
System Status Block
CPS
Clamp Close Profile Status Block
IPS
Injection Profile Status Block
HPS
Pack/Hold Profile Status Block
PPS
Plastication Profile Status Block
OPS
Clamp Open Profile Status Block
EPS
Ejector Profile Status block
RLS
Inject ERC Values Status Block
CLS
Clamp and Eject ERC Values Status Block
Word and bit Numbering
The QDC module stores data in command and status blocks. Each word
location in a command or status block is identified by an alphanumeric
code containing the block acronym and word number. For example, word
09 of the Module Configuration Command Block (MCC) is identified as
MCC09.
Identify bits in a word location by adding bit numbering to the abbreviated
word location. For example:
Specific: MCC09-B15
General: MCCxx-Byy
where:
MCC = Module Configuration Command Block
xx=word number (01-64)
B = bit identifier
yy = bit number (00-15)