Rockwell Automation 2711 PANELBUILDER SOFTWARE USER MANUAL User Manual
Page 121
Creating a Sample Application File
Chapter 5
5-7
b.
Set Module Group to 1.
c.
Set High or Low Byte to High.
d.
Set File Size to 5. This sets the size of the block transfer to 5
words.
4.
When the parameters are set, select Update Block Definition and
press Enter to save the changes and return to the Block Transfer
window.
5.
Choose Quit to return to the Communications menu.
Set the Baud Rate
1.
Choose PLC Baud Rate from the Communications menu to set the
baud rate for PLC communication.
Figure 5.9
Communications Menu
22040
FILE MENU: Screens Windows Options Communicup Exit
Communications
PLC Type
PLC-5/15 integral
Rack Assignment
Block Transfer
PLC Baud Rate
57.6K
Pass-Through Configuration
Quit
2.
Set PLC Baud Rate to 57.6K, and press Enter.
3.
Choose Quit to save the setting and return to the File menu.