Information and Alarm Windows

Chapter 7

7-22

Choosing the Window Type

Figure 7.22

Window Type

Alarm Window

23601

Messages

Window Type

Single Line

Window Look

Window Control Address

Acknowledged Alarm Number Address

Acknowledge Button Address

Options

Quit

Full

Single Line

Window Type allows you to choose either a Full or Single Line Alarm
window. The Full Alarm window includes buttons to silence the alarm,
acknowledge the alarm or view the Alarm Status display or Alarm History
Screen (see

Figure 7.12

). The single line display has no buttons, and allows

operator access to any buttons on the current screen (see

Figure 7.13

).

IMPORTANT: With the single line Alarm window, the operator can only
acknowledge alarms in the Alarm History Screen. (Alarm windows can be
cleared by the PLC controller—see PLC Controlled Clear Window, at the
end of this chapter.) When you design your operator screens, be sure to
include a way for the operator to access the Alarm History Screen.

Setting the Window’s Appearance

Choose Window Look in the Alarm Window menu to define the appearance
of the Alarm window. Both Full and Single Line Alarm windows allow
foreground and background color, blink, and underline choices.

For the Full Alarm window you can also define:

character height; (either single and double)

how many messages will be visible (1 to 19 single height, 9 double

height). This also defines how large the window will be on the screen

With the single line Alarm window, you can choose whether the window
will appear at the top of the screen or the bottom of the screen. Be sure that
the single line window will not block operator access to important buttons
when it appears.