Chapter 6

6-25

Programming Terminal Configuration

Your development computer (PC) must be configured to communicate with
the DH+. This requires defining the address of the PC on the network and
the type of hardware driver used.

These settings are stored in the PanelBuilder Defaults file and become the
new defaults for future downloads.

Figure 6.24

Programming Terminal Configuration Menu

22573

Programming Terminal Configuration

Programming Terminal DH+ Address

0

DH+ Hardware Driver

1770-KF2/1785-KE

Get 6200 Parameters

Pass-Through Utility Directory

C:\PASSTHRU

Quit

You can use the first two menu items to enter these values manually, as
follows:

Programming Terminal DH+ Address: This option defines the

address and parameters of the PC you will be using to download files.
Enter a value (0-77 octal). The default is 0.

DH+ Hardware Driver: Choose from:

1770-KF2/1785-KE (choose a port, baud rate, parity, half/full

duplex, and error-checking type)

1784-KL (choose between multi-drop or direct connection types)

1784-KT/KT2 (you will have to choose a connection type and a

Driver Card Location).

1784-KTK1 (choose a connection type, a Driver Card Location,

and an interrupt number)

Get 6200 Parameters: Alternatively, if you have the 6200

Programming software, you can choose to have the addresses and
parameters loaded directly from the 6200 default file, instead of entering
them manually.