Creating a Sample Application File

Chapter 5

5-42

two Momentary (Normally Open) push buttons

one “Return To Previous Screen” button

Add Background Text

You’ve already seen how to add Background Text to a screen. Those
step-by-step instructions are not repeated here, just the parameters you
need to define the text. If you’re not sure how to proceed, use the
instructions for Screen 2.

1.

Text item 1 is the main title “PUMP CONTROLS”:

double-height, double-width text

located at Row 4, Column 24

white foreground with black background

2.

Text item 2 is the selector label “PUMP CONTROLS”:

single-height, single-width text

located at Row 9, Column 24

white foreground with black background

text is underlined (the underline option is found in the Look menu)

3.

Text item 3 is the numeric indicator label “PRESSURE (PSI)”:

single-height, single-width text

located at Row 9, Column 41

white foreground with black background

text is underlined

Add the Control List Selector

The Control List Selector is an object with three different components: the
list of selections, the Up Cursor button, and the Down Cursor button.

When an operator uses the Up or Down Cursor buttons, the PLC records
which of the five selections is highlighted. When the operator presses one
of the Momentary (Normally Open) buttons, the PLC will either start or
stop the associated pump.