Using PanelBuilder

Chapter 3

3-17

Figure 3.14

Memory Limit Information Message

22551

Information

EEPROMs must be installed in the PanelView terminal to support this extended

user memory option. When the EEPROMs are used for extended user memory,

they cannot be used for backup of the Application File.

Press any key to continue.

If, while you are editing your application, you increase the file size beyond
the User Memory Limit setting, the following message will be displayed:

Figure 3.15

Memory Limit Warning Message

22553

Warning

This application exceeds the currently selected user memory limit. This

operation will be completed. However, in order to download this application file

you need to change the user memory limit under Options in the File menu, or

delete one or more objects, messages or screens.

Press any key to continue.

If you do not change the User Memory Limit to accommodate the extra
memory requirements, you will get an error message any time the file size
is critical, when attempting to download application files or create hex
files, for example.

Minimum Push Button On Time extends the time that a button is

actually held on. This option helps to prevent a very quick button press
from being “ignored” by a PLC program or I/O scan.

Cursor Auto Repeat Rate (per Sec.) allows you to set the repeat rate

for certain buttons including: list selectors, arrow keys, alarm window
and alarm status screens.

Cursor Auto-Repeat Start Delay allows you to set a delay before the

repeat function starts, after a button has been pressed.

Time and Date to PLC Controller enables or disables the transfer of

time and date from the PanelView terminal to the PLC controller.

Current Screen Number to PLC Controller sends the current

PanelView screen number to the PLC controller each time the screen
changes.