10ć2 – Rockwell Automation 2711 PANELBUILDER SOFTWARE USER MANUAL User Manual
Page 267

The Objects
Chapter 10
10-2
Retentive Objects
When the power is switched off and on, retentive objects hold their values
or revert to preset values, depending on whether the PanelView terminal’s
Preset Operations screen is configured as Last State or Preset. When the
terminal is switched from Run mode to Configure mode, retentive objects
hold their values.
Non-retentive objects revert to a default value when the mode is switched
or the power is turned off and on.
The following objects are retentive:
Maintained Push Button
Interlocked Push Button
Control List Selector (with and without Enter key)
Increment and Decrement Value Buttons
Set
Value
Button
Set Bit Cursor Point
Numeric Input Cursor Point
Numeric Keypad Entry Button
Numeric Keypads (small and large)
Scrolling List Object
Complete information on retentive objects, including special notes on how
to use them, is in the section About Retentive Objects at the end of this
chapter.