Information and Alarm Windows

Chapter 7

7-13

ATTENTION: Do not use your PanelView terminal as a
primary warning device or indicator of a critical or dangerous
situation. An operator’s response to a critical or dangerous
situation must never depend on software or solid state
electronics. All critical alarm indications and any critical host
controller responses must employ redundant and hard wired or
mechanical interlocks. “Critical” means any situation that could
result in physical injury, product damage or significant process
down time.

Alarm Messages

When the PLC controller triggers an alarm message, PanelView displays
the alarm message in the Alarm window. Time and date of occurrence are
displayed with the alarm message.

Figure 7.12

The Full Window with one Alarm Message

20225

Alarm message number 1

01:52:28 PM 06/21/93

Cursor

Up

Acknowl

Alarm

Cursor

Down

The Full Alarm window can display up to 19 single-height messages. If the
PLC controller triggers more alarm messages before you clear the window,
the existing message shifts down, and the new messages are added to the
top of the list.