Rockwell Automation 2755 Enhanced Decoder Series B User Manual

Page 111

Advertising
background image

7–23

Configuration: Scanner Control, Primary Match Table, Discrete I/O

Publication 2755-833

Figure 7.4 AutoLoad using AutoLoad (INPUT)

First Valid Package Read

After AutoLoad

Notes: AutoLoad is set for outputs 1, 2, and 3 and applies to match code entries 1, 2, and 3.

Output 8 is set to AutoLoad (INPUT), which activates the AutoLoad function for entries 1, 2, and 3

Symbols per package parameter is set to 1.

AutoLoad Configuration after Next AutoLoad (INPUT)

Notes:

Output condition changes from AutoLoad to Match Entry for Output 1.

Bar code data loaded into match code table entry 1.

Notes: Table is restored to saved configuration.

when an input signal is momentarily applied.

No new data scanned

The output condition for outputs 2 and 3 does not change from AutoLoad since Symbols/Package

Output condition changes from Match Entry to AutoLoad for Output 1.

setting has been satisfied.

Output duration must be

set for outputs and LEDs to operate.

AutoLoad Configuration at AutoLoad (Input)

(Saved Configuration)

Ready to Autoload next symbol read into match code table

Advertising