Configuration: Scanner Control, Primary Match Table, Discrete I/O
Publication 2755-833
Figure 7.4 AutoLoad using AutoLoad (INPUT)
First Valid Package Read
After AutoLoad
Notes: AutoLoad is set for outputs 1, 2, and 3 and applies to match code entries 1, 2, and 3.
Output 8 is set to AutoLoad (INPUT), which activates the AutoLoad function for entries 1, 2, and 3
Symbols per package parameter is set to 1.
AutoLoad Configuration after Next AutoLoad (INPUT)
Notes:
Output condition changes from AutoLoad to Match Entry for Output 1.
Bar code data loaded into match code table entry 1.
Notes: Table is restored to saved configuration.
when an input signal is momentarily applied.
No new data scanned
The output condition for outputs 2 and 3 does not change from AutoLoad since Symbols/Package
Output condition changes from Match Entry to AutoLoad for Output 1.
setting has been satisfied.
Output duration must be
set for outputs and LEDs to operate.
AutoLoad Configuration at AutoLoad (Input)
(Saved Configuration)
Ready to Autoload next symbol read into match code table