16–17

PCCC Host Commands

Publication 2755-833

1

3

0

2

4

STS= 00H

TNS

High Byte

Low Byte

MSB

LSB

CMD= 06H

Read Diagnostic Status Command

0

STS= 00H

High Byte

Low Byte

MSB

LSB

2

Read Diagnostic Status Reply

1

3

FNC=03H

4

EE

00

6

21

22

8

”2”

22

10

”5”

”7”

12

”–”

”5”

14

”D” (or “S”)

”D”

” ”

”1”

” ”

” ”

00

00

00

00

00

00

00

00

5

7
9

11

13

15

17

19

21

23

25

27

16

18

20

22

24

26

CMD Reply = 46H

TNS

The Series/Revision byte indicates the product series and revision
levels. The three most significant bits indicate the series and the
other five bits indicate the revision. For example, a value of 0 = A,
1 = B, 2 = C.

Series A, Revision A returns as

Series B, Revision C returns as

000

00000

001

00010

A

A

B

C