Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 251
15–63
ASCII Host Commands
Publication 2755-833
NM - Configure Default No-Read String
Command Format:
NMIIstring
Function:
Defines a no-read message for bar codes that
could not be scanned or decoded. No-read
messages are optionally included in messages
sent to the host.
Parameters:
ll
string
Command
Parameter
Parameter Function
Valid Values
ll
Length of no-read message
00 to 32
①
String
No-read message characters
Up to 32 characters
① A zero length string disables a no read string.. A nonzero length string
enables the no read string
Response:
= rr <end>
rr =
response code
<end> =
end of message control code
Example:
Command:
NM07NO-READ
Parameters:
07NO-READ
Command
Parameter
Parameter Function
Values
ll
Length of no-read message
07
String
No-read message characters
NO-READ
Response:
= 00CR
00 =
command complete
response code
CR =
end of message control code
for Carriage Return