11–4

Configuration: Host Message Format

Publication 2755-833

Example 3: If a No-Read occurs, the decoder transmits:

End Message Characters

Package Count

End of Package Double Delimiter

No-Read Message

Header Message

Field Delimiter

#L7–AData From Scanner A ” NO-READ ” ” 000015CRLF

Start Character

Source Identifier

Note: Message packages can consist of both bar code strings and
no-read strings.

The parameters listed below include those used to control the
message format of bar code data that is sent to the host. Each
parameter is defined below. The options for each parameter are
summarized in a table, and explained more fully in the text. Where
appropriate, the default setting for each parameter is displayed in
bold letters in the table.

Start Character

Field Type Options

Edit Numeric

ASCII Numeric
(1 – 255)
255 = None

Defines the three digit decimal ASCII starting character for every bar
code message sent to the host. The default is None or 255, which
indicates no start character.

Source Identifier for AUX, A, and B

Field Type Options

Edit Text

Any ASCII Character
String
(4 chars max)
Blank

Defines a 1 to 4 character identifier to include in each message sent
to the host. The string identifies the source device for the data
contained in the message. The default for each field is Blank, which
means a source identifier is not defined. Example source identifiers
are SCNA, SCNB, and AUX.

Host Message Parameters