Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 217
![background image](/manuals/580788/217/background.png)
15–29
ASCII Host Commands
Publication 2755-833
OC - Set Output Condition and Output Duration
Command Format:
OCnctttt
Function:
Sets the condition that will activate an output
and the length of time (in milliseconds) the
output is activated.
Parameters:
nctttt
Command
Parameters
Parameter Function
Valid Values
n
Output number
1 through 8
c
Condition activates output
0= None
1= Read (Package)
2= No-Read (Package)
3= Match Complete
4= Match Entry
5= Read and No-Match
6= No-Read or
No–Match
7= Auto Load
8= Auto Load (Input)
①
9= Host buffer full
A= Host buffer overflow
tttt
Time (in milliseconds) that
output is activated.
0000, 0010 to 9999
(milliseconds)
0000 disables condition
① The AutoLoad (Input) function applies only to output 8.
Response:
= rr <end>
rr =
response code
<end> =
end of message control code