ASCII Host Commands
Publication 2755-833
RN - Save Configuration to Storage Memory and Restart
Command Format:
RN
Function:
Saves current configuration in to storage
memory and restarts the decoder. Operation then
resumes using the new configuration parameters.
Parameters:
None
Response:
= 97 <end>
97=
Indicates the command was
received and the decoder is
resetting. The reset takes
approximately 5 seconds.
<end>=
end of message code
SA - Save Configuration to Storage Memory (No Restart)
Command Format:
SA
Function:
Saves current configuration to storage memory.
Parameters:
None
Response:
= 00 <end>
00 =
Indicates the command was
received
<end>=
end of message code
Important: Host communication parameter
changes do not take effect until the decoder is
restarted.