Rockwell Automation 2755 Enhanced Decoder Series B User Manual
Page 250
Advertising
![background image](/manuals/580788/250/background.png)
15–62
ASCII Host Commands
Publication 2755-833
HM - Configure Header Message
Command Format:
HMIIstring
Function:
Defines a header message for bar code data.
Parameters:
llstring
Command
Parameter
Parameter Function
Valid Values
ll
Length of header message
00 to 32
①
String
Header message characters
Up to 32 characters
① A zero length string will disable the header message.
Response:
= rr <end>
rr =
response code
<end> =
end of message control code
Example:
Command:
HM03A-B
Parameters:
03A-B
Command
Parameter
Parameter Function
Values
ll
Length of header message
03
String
Header message characters
A-B
Response:
= 00LF
00 =
command complete
response code
LF =
end of message control code
for Line Feed
Advertising